94
6OPERATIONAL MALFUNCTIONS
6.2 ERROR MESSAGES
ALS
350
450
E_14 Too many products between product
sensor and dispensing edge.
Product sensor located too far from dispensing edge:
A maximum of 7 products can be located between
the product sensor and the dispensing edge.
£Change the position of the product sensor.
£Subsequently correct the POS setting.
The product triggers several start signals, caused by
reflections, for example:
£Adjust the product length (PRDL function).
E_15 Short circuit
or
Overload of outputs from CN10
A check of the connections and output signals by
servicing technicians is required; refer to the service
guide.
ER-U Software error £ Press the ENTER key.
£ Make note of all the information that is displayed on the
control panel.
£ Make note of what happened before the error occurred.
£ Inform Avery Dennison’s customer service.
ER-I Software error
ER-D Software error
ER-T Software error
ER-A Software error
Message Description Possible causes and remedies

Table of Contents