34
Model E1070 Indicator Service Manual
Table 2
Printing commands chart
Dec HEX Token Application Group Parameter
128 80 GWT(,n) Gross Weight [1] Weight OPTIONAL, (ASCII)
Range: (‘2’-‘9’), Indicator Default: ‘6’
129 81 NWT(,n) Net Weight [1] Weight OPTIONAL, (ASCII)
Range: (‘2’-‘9’), Indicator Default: ‘6’
131 83 SAT(,n) Semi-Auto Tare [1] Weight OPTIONAL, (ASCII)
Range: (‘2’-‘9’), Indicator Default: ‘6’
132 84 UN Units Weight
135 87 ID Scale Serial Number Misc
136 88 TIM,x Time Time MANDATORY (DECIMAL)
Range: (0-2), Editor Default:1
0= Format as set/active in indicator
1= hh:mm
2= hh:mm AM/PM
137 89 DAT,x Date Date MANDATORY, (DECIMAL)
Range: (0-4), Editor Default:1
0= Format as set/active in indicator
1= MM/DD/YY
2= MM/DD/YYYY
3= DD/MM/YY
4= DD/MM/YYYY
138 8A TTV,n Target Value Trip MANDATORY, (HEX #s)
Range: (‘31’-‘33’), Editor Default: ‘1’
For target weights
142 8E CLA(,n) Checkweigher Checkweight OPTIONAL, (ASCII)
‘Low Accept’ value [1] Range: (‘2’-‘9’), Indicator Default: ‘6’
143 8F CHA(,n) Checkweigher Checkweight OPTIONAL, (ASCII)
‘High Accept’ value [1] Range: (‘2’-‘9’), Indicator Default: ‘6’
144 90 RAV,n Active Recipe Recipe MANDATORY, (HEX #s)
Ingredient x ‘Actual’ value Range: (‘31’-‘38’), Editor Default: ‘1’
For target weights in recipe
145 91 RTV,n Active Recipe Recipe MANDATORY, (HEX #s)
Ingredient x ‘Target’ value Range: (‘31’-‘38’), Editor Default: ‘1’
For preact values in recipe
146 92 RPV,n Active Recipe Recipe MANDATORY, (HEX #s)
Ingredient x ‘Preact’ value Range: (‘31’-‘38’), Editor Default: ‘1’
For target weights in recipe
147 93 RIU,n Active Recipe Recipe MANDATORY, (HEX #s)
Ingredient x units Range: (‘31’-‘38’), Editor Default: ‘1’
For ingredient units (lb or kg for weight
based ingredients; sec for time based
ingredients; cnts or gallons for pulse
counter based ingredients). To be
printed after the target or actual ingredi-
ent value.
148 94 PCE Piece Weight Count
149 95 CNT Current Count Value Count
151 97 GTO Gross Accumulator Weight
153 99 STO Net Accumulator Weight
155 9B PLU PLU NumberData PLU