EasyManuals Logo

Avery Weigh-Tronix evolution Series User Manual

Avery Weigh-Tronix evolution Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Model E1065 Indicator User Instructions 73
Power requirements
85-265 Volts AC @ 0.3Amp maximum
50/60 Hz
Excitation
+/- 5 volts DC
Supports up to eight 350-ohm weight sensors
Analog signal input range
+/-60 mV
Analog signal sensitivity
0.2 µV/V/divisions minimum
1.0 µV/V/divisions recommended
Calibration
2 to 5 points stored
Operational keys
Twenty-two keys: Tare, Select, Zero, Print, Units,
F1, Clear, Mode, Escape, Enter, On/Off, Decimal,
0-9 numericf
Operational annunciators
Center of Zero, Motion, Gross, Net, Tare,
Under/Target//Over
Units of measure (LB, KG)
Print, OP1, OP2, OP3, Pt Tare
Display
Six-digit, seven-segment, 0.8-inch high, LED
Display rate
Selectable (1, 2, 5, 10)
Analog to digital conversion rate
100 times per second
Unit of measure
Pounds, kilograms, custom
Capacity selections
999,999 with decimal located from zero to five
places
Incremental selections
Multiples and sub-multiples of 1, 2, 5
Programmable selections
Zero range, motion detection, automatic zero
tracking, five-point linearization.
Time and date/RAM
Battery backed up real time clock and RAM
standard
Internal resolution
53,687,100 counts per mV/V per second
Harmonizer™ digital filtering
Fully programmable to ignore noise and vibration
Standard inputs
Three logic level inputs for: Zero, Print, Tare, Units,
F1, Start and Stop
Standard outputs
10/100 Ethernet (Modbus/TCP, TCP/IP, SMTP,
DHCP, Ethernet/IP)
PROFIBUS DP
DeviceNet
Three outputs
Two serial ports
RS-232/422/485 (SensorComm) - one
RS-232 or 20mA current loop
Serial Command Inputs/Outputs
Programmable serial response to ASCII character
input
SMA protocol, Broadcast, Enquire, RD-4100, E-
series remote display
Self diagnostics
Display, keys, inputs, outputs, serial port, A to D
converter
Circuitry protection
RFI, EMI, and ESD protection
Options
Analog output/Pulse input
Remote I/O
ControlNet
TM
•TIU3
Washdown remote foot control
Operating applications
General weighing, Accumulation, Batching,
Counting, Checkweighing, Peak measurement,
Remote display
Operating temperature
14 to 104° F (-10 to 40° C)
-40 to 140° F (-40 to 60° C) non-legal
Up to 95% non-condensing humidity
Enclosure
Stainless steel NEMA 6/4X
Specifications
9

Other manuals for Avery Weigh-Tronix evolution Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix evolution Series and is the answer not in the manual?

Avery Weigh-Tronix evolution Series Specifications

General IconGeneral
BrandAvery Weigh-Tronix
Modelevolution Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals