95
Model E1070 Indicator Service Manual
11. Press the UNITS key. . .
MODE is displayed. Use this to select the sampling mode; Bulk or
Dribble.
Bulk sampling In this sampling method you place the
specified number of items on the scale all at
once (in bulk) and the scale automatically
starts to calculate piece weight when the
weight stabilizes. The count is then dis-
played.
Dribble sampling In this sampling method you count out the
specified number of items onto the scale
and when you are ready, press the a key
and the scale starts to calculate piece
weight and then shows the count.
12. Toggle between the choices by using the TARE or UNITS key. Press
ENTER when your choice is displayed. . .
MODE is displayed.
13. Press the UNITS key. . .
CLEAR is displayed. Use this item to clear all the information
stored for this application. WARNING - Only do this if you are
sure you want the information permanently removed!
You may want to print out the report before clearing all the infor-
mation. See step 2 in this section.
14. Press the PRINT key to clear all the information
OR
Skip to step 15. . .
SURE? is displayed. This is asking if you are sure you want to
clear the information. If you are, press the ENTER key. If you do
not want to clear the data, press the SELECT key. . .
CLEAR is displayed.
15. Press SELECT. . .
COUNT is displayed.
Supervisor Menu—(continued)