EasyManuals Logo

Avidyne EX600 User Manual

Avidyne EX600
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
Reference
Avidyne EX500/EX600 MFD -162- 600-00078-001 Rev 05
Loss of Radar
Data
Communication with the
Radar sensor has been lost.
No data is available.
Momentarily select
Standby, then reselect
mode. Have
maintenance check R/T.
Radar Error
An error has occurred in the
Radar sensor system. R/T
Fault (general).
Contact Maintenance.
Radar Error
Cleared
The previously reported
error in the Radar sensor
system has been corrected.
Acknowledge
Radar Failure
The Radar system has
failed. This error will not be
cleared until the EX500/
EX600
is shut down and
restarted.
Momentarily select
Standby, then reselect
mode. Have
maintenance check R/T.
Radar Messages
& Colors
Meaning Recommended
Pilot Action

Table of Contents