6.4 Cable management
The cables must be adequately fastened to
the structure to avoid causing the cables to
be accidentally unplugged.
You must use cables suited to the type of
installation you are using.
For conductor section and cable sheath
diameters which can be used, please refer
to the technical data in the relevant chapter
(15 Technical data, page 30).
Insert the cables into the cable glands.
If the cable has a pre-assembled connector, replace
the gasket inside the cable gland with the one
supplied. Insert the Ethernet cable in the gasket as
illustrated in the figure (Fig. 12, page 18). Pass the
cable with connector RJ45 through the M20 cable
gland.
Fig. 12
M20
M16
M16
Power supply
Digital I/O
Ethernet
Fig. 13
Tighten the cable glands.
Pay attention to the fixing. Tightening
torque : 1.5Nm (±0.2Nm) for M16 cable
glands, 2Nm (±0.2Nm) for M20 cable
glands.
If a cable gland does not have a cable inserted, a
specific cap must be inserted for closure. Always close
the cable glands with the stated tightening torque.