P/N 133487 47
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
SC22-3 Safety Controller
Instruction Manual
Configuration — Onboard Interface
5.3.3 Confirm Configuration
If any changes are made to a configuration, it must be confirmed
again before it can be used in a safeguarding application. Select
Confirm Configuration and press OK.
The Confirm Configuration menu will appear. To confirm, you will
review the safety-critical configurations for the inputs, the safety
outputs, and the system settings. An unchecked box in the
Confirm Configuration menu indicates the safety-critical settings
have not yet been confirmed.
Confirm Configurations of Inputs — Select Confirm Inputs
and press OK. The next menu lists all of the safety inputs in the
configuration. Use the up/down arrows to select an input and
press OK.
The next series of menus lists the safety-critical configurations
for this input, including some or all of the following (depending
on the device):
• Circuit type
• Safety output mapping or input mapping
• Reset logic (manual or automatic)
• Simultaneity (simultaneous or concurrent)
• Startup test
• Mute time limit
• Enabling device time limit
• Bypass time limit
• Debounce times (if not equal to default)
Press OK after reviewing each setting.
Repeat the confirmation process for each input. When all inputs
have been confirmed, each input in the display will have a check
mark:
To continue confirming the configuration, select <Done> and
press OK.
Confirm Configuration of Safety Outputs — Select Safety
Outputs and press OK. Use the up/down arrows to select a
safety output and press OK. The next series of menus displays
the safety-critical configurations for the selected safety output.
Review each setting and press OK.
When the safety output is confirmed, a checked box should
appear in front of it, on the Confirm Outputs screen. Repeat the
confirmation process for each safety output. When all safety
outputs have been confirmed, each output in the display will have
a check mark:
After each output is confirmed, select <Done> and press OK.
The Confirm Configuration menu reappears, indicating whether
the inputs and safety outputs are confirmed. If any boxes
do not have a check mark, repeat the confirmation of those
components.
Confirm System Settings — The last step is to confirm the
system settings. Select System Settings and press OK. The
next series of menus lists the safety-critical system settings.
Review each setting and press OK to confirm.
Final Confirmation Step — After all of the safety-critical
configuration settings are confirmed, the configuration can be
used in a safeguarding application. If any changes are made
to the configuration, the confirmation process must be
repeated.
Select <Done> and press OK to exit the Confirm Configuration
menu. Press ESC or go to Exit Configuration to return to Run
mode.
Confirm Safety
Outputs
Edit
Password
Set
Language
Confirm
System Settings
Confirm
Inputs
Receive File
from XM
Send File
to XM
Erase
Configuration
System
Options
(Section 5.3.4)
Configuration
File
(Section 5.3.2)
Confirm
Configuration
(Section 5.3.3)
Conguration
Mode
Configuration
Mode
(Section 5.3)
Exit
Configuration
(Section 5.3.4)
Edit
Configuration
(Section 5.4)
← OK
ESC →
← OK
ESC →
← OK
ESC →
← OK
ESC →
← OK
ESC →
Enter Password
(Section 5.3.1)
Configuration Mode continued