Configuring the Camera
4-10 BASLER A202k
DRAFT
4.2.4 Commands for Setting Camera Parameters
4.2.4.1 Video Data Output Mode
Purpose: To set the video data output mode or to read the current video data output mode setting. See
Sections 2.5.4.2 for an explanation of the available video data output modes.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0xC0 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0xC0 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0xC0 0 1 1 Byte
Response: None
Data Format: Byte 1 An ID that specifies the data output mode
(see the table below).
ID Output Mode
0x01 Dual 8 Bit mode
0x03 Dual 10 Bit mode