Configuring the Camera
4-26 BASLER A202k
DRAFT
4.2.6.3 Select the Startup Pointer
Purpose: The Startup Pointer is used to tag the configuration set that will be copied into the Work Set
at power on (see Section 3.11).
The write command is used to set the Startup Pointer to the Factory Set or to one of the User
Sets.
The read command returns the Set ID for the current setting.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x47 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0x47 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0x47 0 1 1 Byte
Response: None
Data Format: Byte 1 An ID that specifies the set.
(see the table below).
Set ID Set
0x00 Factory Set
0x01 User Set 1
0x02 User Set 2
0x03 User Set 3
0x04 User Set 4
0x05 User Set 5
0x06 User Set 6
0x07 User Set 7
0x08 User Set 8
0x09 User Set 9
0x0A User Set 10
0x0B User Set 11
0x0C User Set 12
0x0D User Set 13
0x0E User Set 14
0x0F User Set 15