Doc. ID Number Date Changes
DA 044001 3-July-2001 Initial release covering prototype cameras only.
DA 044002 26-October-2001 Initial release covering series production cameras.
DA044003 04-March-2002 Update to camera version 1.03:
Changed the minimum high time for the ExSync signal from 1 µs to
4 µs. (Sect. 2.4.1, for example)
Changed the exposure time offset to 94.5 µs. (Sect. 3.2)
Changed the minimum setting for Timer 1 from 10 µs to 6 µs.
(Sections 3.2.1.3, 3.2.2.1, 4.2.4.3, 6.2.1)
Changed the decimal setting for 0 dB from 237 to 288.
(Sections 3.5.1, 3.5.2.1, 4.2.4.10, 4.2.4.12)
Changed the corresponding equations. (Sections 3.5.1 and 3.5.2)
Simplified the No Image troubleshooting chart (Section 6.2.1).
Added more frame grabber configuration file formats to Sect. 6.2.3.