A: PL120100.057
B: PL120100.057
E: 03.93 / T. Weiß
G: 06.93 / T. Weiß
Chapter: 5.7
Page: 3
?
Structure and Function
CA 16
Digital output card
For outputting 16 digital signals with a maximum capacity of
2.5 A.
Each output is tested for overload and short-circuiting. If this
monitoring function reacts, all output cards of the control
system are deactivated. An LED indicates the defective
output card. After defect elimination the machine is restarted
by pressing the “Netz Aus/Ein” key.
Digital input card
For inputting 32 digital signas.
Power pack
Power supply for the entire control system. 23 VDC supply;
a voltage tolerance of +/- 20% has no influence on the output
voltage. An LED indicates that the machine is ready for
operation.
5.7.2 UNILOG 1020 user manual