EasyManua.ls Logo

Battenfeld PLUS 250/50 - Restart After Emergency Stop; Machine Shutoff

Battenfeld PLUS 250/50
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
A: PL120100.060
B: PL120100.060
E: 03.93 / T. Weiß
G: 06.93 / T. Weiß
Chapter: 6
Page: 2
6.2 Starting the machine after EMERGENCY STOP
After pressing the EMERGENCY STOP button, eliminate the
malfunction or error or external cause of EMERGENCY
STOP (i.e. peripheral device, e.g. robot) and unlock the
EMERGENCY STOP button by rotating it in the direction of
the arrow.
6.3 Machine shutoff
The closing unit should be returned to the normal position
(Open mould). If necessary, the piece can now be removed
from the mould by means of the ejector. The injection unit
should also be returned to its normal position (Withdraw
injection unit).
Furthermore, press the “STOP” key and set the heating
selection switch at “0”.
Shut off the machine by pressing the master switch on the
control box. If possible, the master switch should always be
activated without load.
If the injection moulding machine is out of operation for a
longer period of time, all plain parts of the machine should be
covered with an anticorrosive. The residual melted material
must be removed from the screw cylinder and the screw itself;
these parts must also be purged with polyethylene.