Transport - Siting
A: PL120100.040
B: PL120100.040
E: 03.93 / T. Weiß
G: 06.93 / T. Weiß
Chapter: 4
Page: 3
4.3 Siting of machine
No special foundation is required for siting the machine. The
machine frame contains borings (3 x M 16) for fastening the
vibration-absorbing elements. The machine must be balanced
properly before startup.
4.4 Oil filling
The combined filling and ventilation aperture becomes
accessible by screwing off the cover sheet at the back of the
machine. 125 l (33 gal) of hydraulic oil are required for the first
filling of the integrated oil tank.
Only fill the tank with clean hydraulic oil, purity class 15/
12 in keeping with ISO standard 4406!
The oil level must be checked daily.
The oil inspection glass is situated in the bottom right area of
the machine front.
An oil change should be carried out after approximately
4,000-5,000 operating hours. The quality of the hydraulic oil
must be checked by an expert provided by the oil supplier.
Special attention should be paid to waste oil disposal. This
must correspond to the legal provisions of the respective
countries.