Chapter 7: Maintenance
7.1 General
The machine will only work properly and without hitches if it
is regularly serviced. We recommend cleaning the machine
every day to remove impurities and to clean it thoroughly
each week.
The protecting guard and control panel must always be kept
free of any type of impurity. Please bear in mind that dust and
granulated material are especially hazardous to electric and
hydraulic components.
7.2 Maintenance instructions
Checkup time Checkup measures
Daily
Check all safety devices (see chapter 2)
Check oil level
Check oil filter indicator (not necessary if electrical filter
monitoring device was installed)
500 working hours
Check overall condition of mould (visual checkup)
Clean control box filter
2,500 working hours
Operating manual is kept close to the machine and is in good
condition
Lubricate closing platen support
Check Emergency-Off circuit
Check whether heater bands are firmly installed and in their
correct position
Check heater bands with respect to functioning and accumulated
dirt
5,000 working hours
Visual checkup of the electrical components
Clean control box
Exchange control box filter
Exchange diaphragm of cooling water valve
Check wear and centre position of nozzle
Check oil quality (and exchange oil if necessary)