4
P2138
P2139
P2140
This parameter value is used as CAN baudrate if one of the b maXX
®
1000 hardware DIP
switches is ON (see ZP0870). ZP0871 is used as CAN baudrate if all DIP switches
are OFF.
P2138
Benutzerdatensatz 19 0 to 65535
EE Data set for use 19 0
ON BM_u_DataSet19 1:1 -
P2139
Benutzerdatensatz 20 0 to 65535
EE Data set for use 20 0
ON BM_u_DataSet20 1:1 -
P2140
CAN baudrate 0 to 5
EE CAN baudrate for CAN with switch on 2
STOP BM_u_CANBaudrateWithSwitchOn 1:1 -
Value Meaning
0 1000 kbaud
1 500 kbaud
2 250 kbaud
3 125 kbaud
4 100 kbaud
5 50 kbaud