Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
152
of 208
4.3
P2141
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2141– default value is 21.
If ZP2148– > 0, ZP2141– = ZP2141–
⋅ ZP2148–
ZP0870– (b maXX
®
1000 CAN address) is equal to the value of ZP2141–, if the DIP
switch setting is 1.
ZP2148– = 0
ZP2148– > 0
P2141
Adresse-Einstellung für DIP-Schalter 1 0 to 127
EE Address setting for DIP switch 1 21
STOP BM_u_CANBaudrateWithSwitchOn1 1:1 -
DIP switch DIP switch value CAN address setting Default value
1 2 3
1 0 0 1 ZP2141– 21
0 1 0 2 ZP2142– 22
1 1 0 3 ZP2143– 23
0 0 1 4 ZP2144– 24
1 0 1 5 ZP2145– 25
0 1 1 6 ZP2146– 26
1 1 1 7 ZP2147– 27
DIP switch DIP switch value CAN address setting Default value
1 2 3
1 0 0 1 ZP2141– 1 ⋅ ZP2148–
0 1 0 2 ZP2142– 2 ⋅ ZP2148–
1 1 0 3 ZP2143– 3 ⋅ ZP2148–
0 0 1 4 ZP2144– 4 ⋅ ZP2148–
1 0 1 5 ZP2145– 5 ⋅ ZP2148–
0 1 1 6 ZP2146– 6 ⋅ ZP2148–
1 1 1 7 ZP2147– 7 ⋅ ZP2148–