Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
154
of 208
4.3
P2146
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2146– default value is 21.
If ZP2148– > 0, ZP2146– = ZP2146–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2147
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2147– default value is 21.
If ZP2148– > 0, ZP2147– = ZP2147–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2148
ZP2148– DIP switch multiplier is used together with parameters ZP2141– to ZP2147–.
If ZP2148– = 0, ZP2141– to ZP2147– can be set by user to 1 to 127 as CAN address.
If ZP2148– > 0, the values of the DIP switches 1 to 7 are multiplied by ZP2148– and
stored at ZP2141– to ZP2147– .
If all DIP switches = OFF the CAN address is read from ZP2141– to ZP2147–.
For further information see ZP2141– on page 152.
P2146
Adresse-Einstellung für DIP-Schalter 6 0 to 127
EE Address setting for DIP switch 6 26
STOP BM_u_CANBaudrateWithSwitchOn6 1:1 -
P2147
Adresse-Einstellung für DIP-Schalter 7 0 to 127
EE Address setting for DIP switch 7 27
STOP BM_u_CANBaudrateWithSwitchOn7 1:1 -
P2148
DIP-Schalter Multiplikator 0 to 18
EE DIP switch multiplier 8
STOP BM_u_DIPSwitchMultiplier 1:1 -