Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
153
of 208
4
P2142
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2142– default value is 21.
If ZP2148– > 0, ZP2142– = ZP2142–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2143
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2143– default value is 21.
If ZP2148– > 0, ZP2143– = ZP2143–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2144
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2144– default value is 21.
If ZP2148– > 0, ZP2144– = ZP2144–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2145
This parameter together with ZP2148– (DIP switch multiplier) determines the CAN ad-
dress.
If ZP2148– = 0, ZP2145– default value is 21.
If ZP2148– > 0, ZP2145– = ZP2145–
⋅ ZP2148–
For further information see ZP2141– on page 152.
P2142
Adresse-Einstellung für DIP-Schalter 2 0 to 127
EE Address setting for DIP switch 2 22
STOP BM_u_CANBaudrateWithSwitchOn2 1:1 -
P2143
Adresse-Einstellung für DIP-Schalter 3 0 to 127
EE Address setting for DIP switch 3 23
STOP BM_u_CANBaudrateWithSwitchOn3 1:1 -
P2144
Adresse-Einstellung für DIP-Schalter4 0 to 127
EE Address setting for DIP switch4 24
STOP BM_u_CANBaudrateWithSwitchOn4 1:1 -
P2145
Adresse-Einstellung für DIP-Schalter 5 0 to 127
EE Address setting for DIP switch 5 25
STOP BM_u_CANBaudrateWithSwitchOn5 1:1 -