Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
31
of 208
4
P0116
Setting this parameter changes the response time for the slip compensation ZP0114.
P0117
This parameter enables the overheat protection of the motor.
P0118
This parameter is to delay the signals on PTC analog input terminals. 1 unit is 2 ms, 2
units are 4 ms, etc.
P0116
Schlupfanpassung Zeitkonstante 0.05 to 10.00 s
EE Motor slip compensation time constant 0.20 s
STOP BM_u_MotorSlipCompTimeConst 100:1 s -
NOTE
Too long time constants give slow response, too short values can give unstable operation.
P0117
Motor Kaltleiter Überhitzungsschutz Überwachung 0 to 1
EE Motor PTC overheat protection 0
STOP BM_u_PTCOverheatProt 1:1 -
Value Meaning
0 Disable
1 Enable overheat protection by AVI terminal
P0118
Eingangsfilterzeitkonstante Kaltleiterschutz 0 to 9999
EE Input filter time constant of the PTC protection 100 (200 ms)
STOP BM_u_InputFilterTimeConstantPTC 1:2 -