Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
30
of 208
4.3
P0113
Setting this parameter changes the response time for the torque compensation
ZP0112–.
P0114
While driving an asynchronous motor, increasing the load on the drive will cause on in-
crease slip and decrease in speed. This parameter may be used to compensate the slip
by increasing the output frequency. When the output current of the drive is bigger than
the motor no-load current ZP0110–, the drive will adjust its output frequency according
to this parameter.
P0115
This parameter sets the upper limit of the compensation frequency (the percentage of
ZP0111–).
Example:
when ZP0111–= 5 Hz and ZP0115–= 150 %, the upper limit of the compensation fre-
quency is 5 Hz
⋅ 150 % = 7.5 Hz. Therefore, for a 50 Hz motor, the max. output is 57.5 Hz.
P0113
Drehmomentanpassung Zeitkonstante 0.01 to 10.00 s
EE Torque compensation time constant 0.10 s
STOP BM_u_TorqueCompTimeConst 100:1 -
NOTE
Too long time constants give slow response, too short values can give unstable operation.
P0114
Motor Schlupfanpassung 0.00 to 10.00 %
EE Motor slip compensation 0.00 %
ON BM_u_MotorSlipComp 1:1 -
P0115
Motor Schlupfanpassung Grenze 0 to 250 %
EE Motor slip compensation limit 200 %
STOP BM_u_MotorSlipCompLimit 1:1 -