HB-37420-810-01-25F-EN SMX100 Installation manual.docx Page 20 of 260
Version: 25F
3.2 Characteristic data of device
3.2.1 Basic modules
3.2.1.1 System module SMX100-1(/2, /4x, /5x, /x
(1)
)
Design of module with the following
periphery:
14 Digital inputs
2 Pulse outputs
2 Relay outputs
2/4 pn- or pp- switching outputs
2 Auxiliary outputs
1 diagnostic- and
configuration interface
1 function button
1 7-segment display
1 status LED
14 status LEDs for inputs
2 status LEDs for pulse outputs
2 status LEDs for relay outputs
4 status LEDs for outputs
1 Optional: Communication
interface (/4x, /5x, /x
(1)
)
Characteristics of the module:
• Extendable to:
o max. 126 safe digital inputs,
o max. 36 safe digital outputs,
o max. 80 sichere digitale I/O’s,
o max. 50 safe relay outputs,
o max. 34 axiliary outputs
o and/or 12 safe axes
• Logic processing up to Pl e acc. to EN ISO 13849-1 or SIL 3 acc. to EN 61508
• Freely programmable Modular controller for up to 3000 IL instructions
• Logic diagram oriented programming
• Pulse outputs for cross-shorting detection of digital input signals
• External contact monitoring of connected switchgear (EMU)
• Monitored relay outputs for safety relevant functions
• Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
• Complete speed and position-based safety functions for drive monitoring in accordance
with IEC 61800-5-2 are integrated in firmware
o Spatial functions for safe speed and are monitoring are possible
• Parameter management for expansion modules in base device
• Comprehensive diagnostics functions integrated