HB-37420-810-01-25F-EN SMX100 Installation manual.docx Page 222 of 260
Version: 25F
10 Technical data
10.1 Environmental conditions
Min-, Maximum relative
humidity (no condensation)
10.2 Safety related characteristic data
Max. obtainable safety class
• SIL 3 acc. to IEC 61508
• Category 4 acc. to EN ISO 13849-1
• Performance-Level e acc. EN ISO
13849-1
2-channel with diagnose (1002)
"high demand" acc. to IEC 61508 (high
demand rate)
Probability of an endangering failure
per hour (PFH-value)
SMX121
SMX121-2
SMX122x (1 Axis)
SMX122x (2 Axis)
SMX122-2x
Proof-Test-Interval (EN61508)
20 years, after this time the module must be
replaced