EasyManua.ls Logo

BBH SMX Series - Encoder Types and Their Combination, Diagnostic Data

BBH SMX Series
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
HB-37420-810-01-25F-EN SMX100 Installation manual.docx Page 91 of 260
Version: 25F
4.2.2.3 Encoder types and their combination, diagnostic data
Encoder A
Encoder B
Safe
speed
Safe
direction
Safe
absolute
position
Fault exclusion
DC
1-channel
partial system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
1 x Proxi
1 x Proxi
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required, if common elements are in
use
n.a.
99%
80-90%
Incremental
NC
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required
60%
99%
80-90%
Incremental
Incremental
X
X
n.a.
99%
95%
Incremental
1 x Proxi
X
n.a.
99%
90-95%
Incremental
2 x counter Proxi 90°
X
X
n.a.
99%
90-95%
Incremental
SIN/COS
X
X
n.a.
99%
99%
Incremental
HTL
X
X
n.a.
99%
90-95%
Incremental
Resolver
X
X
n.a.
99%
99%
Incremental
SSI
X
X
X
n.a.
99%
90-95%
SIN/COS
NC
X
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required
90%
99%
90-95%
SIN/COS
Incremental
X
X
n.a.
99%
95-99%
SIN/COS
1 x Proxi
X
X
n.a.
99%
90-95%
SIN/COS
2 x counter Proxi 90°
X
X
n.a.
99%
95-99%
SIN/COS
HTL
X
X
n.a.
99%
95-99%
SIN/COS
Resolver
X
X
n.a.
99%
99%
SIN/COS
SSI
X
X
X
n.a.
99%
95-99%
SSI
2 x counter Proxi 90°
X
X
X
n.a.
99%
90-95%
SSI
SIN/COS
X
X
X
n.a.
99%
95-99%

Table of Contents