5.11.3.7 Connection of proximity switch SMX111x SMX112x
The connection is made via plug connector X23 on the digital inputs I05 … I08.
The exact pin assignment depends on the encoder type and is shown in the connecting plan of
the programming interface.
Note: When using HTL-encoders please bear in mind that the tracks A+ and B+ or A- and B-
must be combined accordingly.
5.11.3.8 Connection of HTL/proximity switch SMX11-2/SMX12-2
The connection is made via plug connectors X27 and X28, or X29 and X30