HB-37420-810-01-25F-EN SMX100 Installation manual.docx Page 241 of 260
Version: 25F
Example of software specification
Monitoring V_Rope to
V_Nominal
Monitoring of differences
between speed of main
drive and rope drive for
maximum value
Digital
incremental
encoder,
tachometer
generator rope
sheave
Monitoring by means of tested
function SLS + SAC with comparison
of speed ranges /analog value
ranges = comparison for diagnose of
the speed detection
Shut-down dual-channel new (see
below)
Permanently
Reset:
Acknowledgement
button
Backstop
Monitoring for reversing
Mechanical limit
switch 22S2
Digital
incremental
encoder
Monitoring by means of tested
function direction monitoring SDI
EMERGENCY
(auxiliary contact
28K4 – reversing)
Reset:
Acknowledgement
button
Step-by-step shut-down
Activation of the safety
brake
Processing of SF in Safe PLC
SF 1.2
SF 1.3.2
SF 1.7
SF 1.8
Digital
incremental
encoder
Standstill monitoring by means of
tested function SOS
Regulator lock
OR
Set service brake
SF 1.15/
Set safety brake
Digital
incremental
encoder,
Monitoring by means of tested
function direction monitoring SDI
28K1 = FORW.
28K2 = BACK
= safe <signals from
control "Frey"""