HB-37420-810-01-25F-EN SMX100 Installation manual.docx Page 60 of 260
Version: 25F
Technical characteristic data SMX132-0(R)/2/D / 132-1(R)/2/D
Safety related characteristic data
Pl acc. to EN ISO 13849-1
PL e
PFH
1)
/ Architecture
9,2 FIT
/Cat 4
Plus in SMX132-xR/2/D
1-kanalig pro Rel 20 FIT (max. 8)
2-kanalig pro Rel 1,0 FIT
(
max. 4)
SIL acc. to IEC 61508
SIL 3
Proof test interval
20 years = max. operation period
General data
Max. no. of expansion modules
-
Interface for expansion modules
Communication interface (/D) or
T-bus connector, pluggable in top-hat rail
Number of safe digital inputs
12 (OSSD capable)
Number of safe digital outputs
pn-, pp-
switching
SMX132-x/2/D
2/4
SMX132-xR/2/D
-
Number of safe digital I/O
SMX132-0x/2/D
-
SMX132-1x/2/D
10
Number of relay outputs
SMX132-x/2/D
2
SMX132-xR/2/D
6
Number of safe analogue inputs
-
Number of auxiliary outputs
SMX132-0x/2/D
2
SMX132-1x/2/D
4
Number of pulse outputs (clock outputs)
2
Type of connection
Plug-in terminals with spring or screw connection
Axis monitoring
-
Encoder interfaces (D-Sub / screw terminal)
-
Encoder technology (See table encoder specifications)
-
SMXGen2 (/2)
Number of safe digital outputs
pn-switching **
2
pp-switching **
4
Electrical data
Supply voltage (tolerance)
24 VDC; 2A (-15%, +20%)
Fuse
X11.1
min. 30 VDC; max. 3,15A
X11.2
min. 30 VDC; max. 10A
Max. power consumption (logic)
SMX132-0x/2/D
4,2W
SMX132-1x/2/D
5,2W
Rated data digital inputs
24 VDC; 20mA, Typ1 acc. to EN 61131-2
Rated data digital outputs
pn-switching
24 VDC; 2A
pp-switching
24 VDC; 2A
Digital I/O 01 05
06 10
24 VDC; 0,5A
24 VDC; 2A ***
Auxilary outputs
24 VDC; 250mA
Pulse outputs
(clock outputs)
24 VDC; 250mA
Rated data
relays
Normally open DC13
AC15
24 VDC; 2A
230 VAC; 2A
Normally closed DC13
(Read back contact)
24 VDC; 2A
Rated data analogue inputs
-
Electrical data (For UL only) SMXGen2 (/2)
Rated data digital outputs
pn-switching
Temperature rating
30°C
24 VDC; 2A (G.P.)
Temperature rating
50°C
24 VDC; 1,8A (G.P.)
pp-switching
Temperature rating
30°C
24 VDC; 2A (G.P.)
Temperature rating
50°C
24 VDC; 1,8A (G.P.)

Table of Contents