AR6201-(X0X)
Page 1-8 DV 14300.03/.04 Issue 5 5/2013
Condition
Section
Cat.
Description
Humidity 6.0 A Standard
Shock and Crash Safety 7.0 B
Fixed-
wing and Helicopter,
standard
Vibration 8.0
S
U
Curve M for Fixed-wing
Aircraft
Curve G for Helicopters
Explosion-proofness 9.0 X N/A
Water-proofness 10.0 X Condensing water
Fluids Susceptibility 11.0 X N/A
Sand and Dust 12.0 X N/A
Fungus Resistance 13.0 X N/A
Salt Spray 14.0 X N/A
Magnetic Effect 15.0 Z Less than 0.3m
Power Input 16.0 B
DC installations with
battery of significant
capacity
Voltage Spike 17.0 A
High degree of protection
against voltage spikes
Audio Freq. Conducted
Susceptibility
18.0 B
DC installations with
battery of significant
capacity
Induced Signal
Susceptibility
19.0 AC
Primary power DC or AC,
400Hz
Radio Frequency
Susceptibility
20.0 SW
Interim High Intensity
Radiated Fields
Emission of Radio Frequency
Energy
21.0 B
Equipment where
interference should be
controlled to a tolerable
level
Lightning Induced Transients
Susceptibility
22.0 A1E3X
Pin test waveform A, level
1
Cable bundle test waveform
E,
level 3
Lightning Direct Effects 23.0 X N/A
Icing 24.0 X N/A
Electrostatic Discharge 25.0 A
Equipment operated in an
aerospace environment
Fire, Flammability 26.0 X N/A