Thechange oftime rangeand monitoring timeis doneby meansof the BEKADiSys software(current versionavailable on
BEKAwebsite).
Setting ranges for number of pulses at progressive distributor:
1to 16pulses (16 notchesà 1 pulse)
10to160 pulses(16 notches à10 pulses)
20to 230pulses (16 notchesà 20 pulses)
100to 1600pulses (16 notchesà 100 pulses)
500to 8000pulses (16 notchesà 500 pulses)
Pulsesetting isdone by meansof the switchesin thecontrol unit window(see 9.1.3 changeparameter).
9.3 Operating mode lubrication duration
The integrated control unit PICO-tronic can define the lubrication duration in operating mode „time-dependent“ „pulse-
dependent“or „speed-dependent“.
9.3.1 Operating mode lubrication duration time-dependent
The time-dependent control of the lubrication duration can set the lubrication time in two setting ranges and the
monitoringtime withhelp of theBEKADiSys software (currentversion available onBEKAwebsite).
Fig.32:
The change of time range and monitoring time is done by means of BEKA-DiSys software (current version available on
BEKAwebsite).
Setting ranges for number of revolutions of motor:
1to 16min. (16 notchesà 1 Minute)
2to 32min. (16 notchesà 2 minutes)
2to 32sek. (16 notchesà 2 seconds)
Timesettingis donebymeans ofthe switch inthe control unitwindow (see9.1.3change parameter).
9.3.2 Operating mode lubrication duration pulse-dependent
The pulse-dependent control of the lubrication duration counts incoming pulses of the
proximity switch, installed at the progressive distributor. If a pulse is missing until the
monitoring time isfinished (standard12 minutes),the control unit shows amalfunction
(see12.3 signalsof the integratedcontrol unit PICO-tronic).
The error is reset by pressing the intermediate lubrication button after the error is
solved.Thepump immediatelystarts a lubrication.
lubrication time
cycle duration
Fig. 33:
© BEKA 201 All rights reserved!6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BEKA PICO Series and is the answer not in the manual?

BEKA PICO Series Specifications

General IconGeneral
BrandBEKA
ModelPICO Series
CategoryWater Pump
LanguageEnglish

Related product manuals