10.6 Set output rate for pump element PE-120 FV
Technical data
Outputrate: 0,04cm to 0,12cm / pistonstroke
33
Regulationof quantity: 6-notchesà 1/2revolutions
Reduction: 0,013cm / notch
3
Allpump elementsare set tofull stroke bydefault.
Removethe screwplug (pos. 1,fig. 52) bymeans ofahex screwAF 5.
Fig.52:
Setthe ouputrate by meansof a flatscrew driverbyturning theset screw (pos.3, fig. 52).
Turnthe setscrew clockwise toreduce output rate.
Turnthe setscrew counter clockwiseto increase theoutput rate.
Themax. strokehas 2,4 mm.This correspondsto 6notches.
Onerevolution ofthe set screwis 0,8 mm.Thiscorresponds to2notches.
As soon as you are ready with the setting, insert the screw plug and sealing ring again (pos. 1, fig. 52). Tighten the screw
plugwith atorque of ±10%.15Nm
If the screw plug is not screwed in, the sealing ring is mising or if the screw plug was not tightened
properly, watercan enter anddamage thesystem.