PL-6000DC/DCX Two-Post Parking Lift 17 P/N 5900273Rev. A6 —July 2024
WARNING Installing your Lift on a surface with more than a 1% slope (0.57˚) could lead to
injury or even death. Only install the PL-6000DC Lift on a level floor. If your floor is
not level, consider making the floor level by cutting, removing, and creating a new
concrete slab or choosing a different location.
Do not install the Lift on cracked or defective Concrete.
Never install the Lift over Concrete expansion or control joints of any kind.
All Anchors must be a minimum of 6 in. (152 mm) away from any expansion seams, control
joints or other inconsistencies in the Concrete.
Never install a Lift on hand-mixed Concrete.
Do not install a Lift on a secondary floor level or on any ground floor with a basement beneath
without written authorization from the building Architect and prior approval of Bend Pak Inc.
Verify the floor is not a post-tension slab. If it is a post-tension slab, contact the building
architect before drilling. Using ground penetrating radar may help you find the tensioned cables.
On Post-tension slabs, a qualified technician is required to identify cable locations prior to
cutting or drilling. If there are no signs indicating a Post-Tension Slab, undertake a careful
examination of the exterior of the slab looking for small circular patching areas about 1.5 in. to 3
in. in diameter, typically 2 to 4-feet apart. These patches indicate the ends of the Post-
Tensioned Cables. Another source of information is your local department of Building and
Safety. Structural plans may be retrieved by Building and Safety to determine if the building has
a Post-Tensioned Slab.
WARNING Cutting through a Post-Tensioned Cable can result in injury or death. Do not drill
into a post-tension slab unless the building architect confirms you are not going to
hit tensioned steel, or you have located it using ground penetrating radar. If a
colored sheath comes up during drilling, stop drilling immediately.
WARNING Use only the Anchor Bolts that came with your Lift. If you use components from a
different source, you void your warranty and compromise the safety of everyone
who installs or uses the Lift.
CAUTION BendPak Lifts are supplied with installation instructions and concrete anchors that
met the criteria set by the latest version of the American National Standard
“Automotive Lifts Safety Requirements for Construction, Testing, and Validation”,
ANSI/ALI ALCTV. You are responsible for any special regional structural and/or
seismic anchoring requirements specified by any other agencies and/or codes such
as the Uniform Building Code (UBC) and/or International Building Code (IBC).