PL-6000DC/DCX Two-Post Parking Lift 63 P/N 5900273Rev. A6 —July 2024
9. Low-Speed and Jerky movement of the Lift Cylinder should be checked to avoid damage to the
Cylinder.
10. Score marks and scraping of the chromium on one side of the Cylinder Rod indicates significant
wear, requiring dismantling of the Cylinder to inspect and remove/replace the worn components.
11. Check the Hydraulic Fluid Port, Vent hole and Wiper Seal at the Cylinder Head End. Replace
broken Seals if leaking is occurring.
To Maintain the Chains:
Regularly inspect the Balancing and Lifting Chains for wear or damage.
Check for wear or abrasion loss. Replace the entire Chain if the length is 2% or more than the
standard length.
Verify the Chain Transmission Wheels are properly aligned, and the Chain is unobstructed.
Keep Chains well lubricated. (High viscosity grease is not recommended. Dirt will readily adhere to
high viscosity grease and ultimately cause excessive wear and friction.
Clean debris from the Chains regularly and check for lubrication.
Replace broken Chain elements immediately.
Lubricate between all inner and outer Chain plates, and Chain drive components.
Apply lubrication evenly to all parts of the Chain.
Chains unused for a long time should be cleaned and lubricated regularly.
Lubricate the Chains based on the environment tables below.
Windy and dusty work environment
Temperature Oil Frequency of Lubrication
-10˚ to 0˚C Machine Oil for Chain Lubrication 20#
Once per week.
0˚ to 40 ˚C Machine Oil for Chain Lubrication 30#
40˚ to 50˚C Machine Oil for Chain Lubrication 40#
50˚ to 60˚C Machine Oil for Chain Lubrication 50#
Windless and clean work environment
Temperature Oil Frequency of Lubrication
-10˚ to 0˚C SR4020
Once every two months.
0˚ to 40 ˚C SR4020
40˚ to 50˚C TX8R
50˚ to 60˚C TX8R
Important: In working environments with high humidity, rust-proof treatment and higher
frequency of lubrication is required, at least once per month minimum.
To clean and protect the Lift:
WARNING Prior to cleaning under the Lift Platform, verify the Platform is secured on its Safety
Locks or resting on the ground and power is locked out to prevent movement.
Regularly clean the Lift Platform and under the Platform using a broom or vacuum.