EasyManua.ls Logo

Benning ST 760 - Individual Tests: Functional Test (Funct.); Funct. Test Explanation

Benning ST 760
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
15.8 Funct. Functional test
Explanation
VDE 0701-0702
VDE 0751-1 /
EN 62353
VDE 0544-4 /
EN 60974-4
Class
Class
Class
Class
Class
Class
Class
I
II
III
I
II
I
II
X
X
-
X
X
X
X
The functional test is intended for the final verification of the
electrical safety and is an obligatory part of the test standards to
be considered:
VDE 0701-0702
VDE 0751-1 (EN 62353)
VDE 0544-4 (EN 60974-4)
Non-electrical functions such as cutting, lifting or turning, etc. must
be checked at a lower level.
The functional test includes the following for all single-phase test
samples:
input voltage
input current
effective power
apparent power
Moreover, depending on the test standard and protection class,
the corresponding leakage current is measured.
Test standard
Protection class
Leakage current
VDE 0701-0702 and
VDE 0544-4
I
IPE
VDE 0701-0702 and
VDE 0544-4
II
ICont
VDE 0751-1
I and II
ILeak
The functional test of single-phase loads is carried out via the test
socket on the appliance tester and must not exceed a maximum
rated current of 16 A.
The functional test of three-phase loads can be carried out using
the BENNING MA 2-16 measuring adapter. The maximum rated
current is 16 A per phase.
All devices and components of the test sample that protect against
the impacts of electricity must be tested for safe operation.

Table of Contents