H71: Accel/Decel Time Scale
Range: 0-2 (Default: 1)
Description: This is used to change the resolution for the acceleration and deceleration
times.
H72: Power on Display
Range: 0 - 13 (Default: 0)
Description: This parameter selects the first parameter to be displayed on the keypad
when the input power is first applied.
102
6 - Parameter Descriptions
Output freq
Accel time
Decel time
Max freq
H70: Max. Freq
Certain freq
Accel time
Decel time
Next target freq
H70: Delta Freq
Display Description Display Description
0 Frequency command (0.00) 7 Multi-Step frequency 3
1 Accel time (ACC) 8 Output current (CUr)
2 Decel time (DEC) 9 Motor rpm (rPM)
3 Drive mode (drv) 10
Inverter DC link voltage
(dCL)
4 Frequency mode (Frq) 11 User display select (vOL)
5 Multi-Step frequency 1 12 Fault display 1
6 Multi-Step frequency 2 13 Operating direction select
Setting Range
Description
Display Select
0 0.01 sec.
The Accel/Decel time is changed by 0.01 sec./10msec.
The maximum setting range is 60 seconds.
1 0.1 sec.
The Aceel/Decel time is changed by 0.1 sec./100 msec.
The maximum setting range is 600 seconds.
2 1 sec.
The Accel/Decel time is changed by 1 second. The
maximum setting range is 6000 seconds.

Table of Contents