5.4 Input/Output Group [I/O]
54
5 - Parameter List
Code
[I/O]
Parameter Name Setting Range
Factory
Default
Adj.
during
run
Page
I0 Jump code 0-64 1 Yes 111
I1 Filter time constant for NV input 0-9999 10 Yes
111
I2 NV Input Minimum Voltage 0 ~ -10 [V] 0.00 V Yes
I3 Frequency Corresponding to I2 0-400 [Hz] 0.00 Hz Yes
I4 NV Input Maximum Voltage 0 ~ -10 [V] 10.0 V Yes
I5 Frequency corresponding to I4 0-400 [Hz] 60.00 Hz Yes
I6 Filter time constant for V1 input 0-9999 10 Yes
112
I7 V1 Input Minimum Voltage 0-10 [V] 0 V Yes
I8 Frequency corresponding to I7 0-400 [Hz] 0.00 Hz Yes
I 9 V1 input max voltage 0-10 [V] 10 V Yes
I10 Frequency corresponding to I9 0-400 [Hz] 60.00 Hz Yes
I11 Filter time constant for I input 0-9999 10 Yes
113
I12 I input minimum current 0-20 [mA] 4.00 mA Yes
I13 Frequency corresponding to I12 0-400 [Hz] 0.00 Hz Yes
I14 I input max current 0-20 [mA] 20.00 mA Yes
I15 Frequency corresponding to I14 0-400 [Hz] 60.00 Hz Yes
I16
Criteria for Analog Input Signal
loss
0: Disabled
1: activated below half of
set value.
2: activated below set
value.
0
Disabled
Yes 113
I17
Multi-function input terminal P1
define
0 FWD Run Cmd
1 REV Run Cmd
2 Emergency Stop Trip
3 (RST)
4 Jog operation command
5 Step freq - Low
6 Step freq - Mid
7 Step freq - High
8 Accel/Decel - Low
9 Accel/Decel - Mid
10 Multi Accel/Decel-High
11 DC brake
12 2nd motor
13 (-Reserved-)
14 (-Reserved-)
15 (UP) command
16 (DOWN) command
17 (3-wire)
18 External Trip A
19 External Trip B
20 Self-diagnostic function
21 PID Enable
22 Exchange between Option
and drive
23 Analog Hold
24 Accel/Decel Disable
0
Yes 114
I18
Multi-function input terminal P2
define
1
I19
Multi-function input terminal P3
define
2
I20
Multi-function input terminal P4
define
3
I21
Multi-function input terminal P5
define
4
I22
Multi-function input terminal P6
define
5
I23
Multi-function input terminal P7
define
6
I24
Multi-function input terminal P8
define
7