I34 - I47: 1st - 7th Accel/Decel Time
Range: 0 - 6000sec.
Description: These codes are applied when the multi-function input terminals (P1,P2,P3)
select the accel/decel time.
117
6 - Parameter Descriptions
Step Freq. FX or RX P8 P7 P6
0 P ---
1 P --P
2 P - P -
3 P - PP
4 PP --
5 PP - P
6 PPP -
7 PPPP
Freq.
Step
0
Step
1
Step
2
Step
3
Step
4
Step
5
Step
6
Step
7
Step
0
P6
P7
P8
FX
RX