46
BIFFI F01-2000 ELECTRIC ACTUATOR
INSTRUCTION AND OPERATING MANUAL
• Disconnect two wires (+) (-) from the main
board.
• Bring the cover to a safe area.
When in a safe area:
WARNING
If the actuator is located in a hazardous area a
“hot work” permit must be obtained unless the
actuator can be moved to a non-hazardous area.
11�3 LITHIUM BATTERY CHANGE
• Isolate the main supply to the actuator and all
other control voltages.
• Open the terminal boards cover.
- Remove the battery cover.
- Replace the battery.
IMPORTANT
The new battery must be the same type as the one
provided: Lithium – SAFT LS 9V.
- Remove the label.