KBF (E5.2)
Constant climate chambers with program control
Service Manual
valid for the following models of KBF, starting with serial no. 09-11327:
Model
order no.
KBF 115 (E5.2)
9020-0139, 9120-0139
KBF 115-UL (E5.2)
9020-0184, 9120-0184
KBF 240 (E5.2)
9020-0150, 9120-0150
KBF 240-UL (E5.2)
9020-0176, 9120-0176
KBF 720 (E5.2)
9020-0108, 9120-0108
KBF 720-UL (E5.2)
9020-0168, 9120-0168
Issue 04-2015 order no. 7001-0203

Table of Contents

Other manuals for Binder KBF 720

Questions and Answers

  • C
    Christine GainesSep 9, 2025
    What to do if my Binder Laboratory Equipment chamber has no function and a dark display?
    • S
      Sarah WoodSep 9, 2025
      If there is no chamber function and the display is dark on your Binder Laboratory Equipment, try pressing on the touchscreen. Also, make sure that the main power switch is turned on.
  • M
    Michael BrennanSep 12, 2025
    How to fix impaired valve function of hose burst protection in Binder Laboratory Equipment?
    • V
      Veronica EvansSep 12, 2025
      To resolve impaired valve function of hose burst protection in your Binder Laboratory Equipment, remove calcifications by using citric acid or acetic acid solutions. Have a plumber inspect the valve.
  • M
    Michael WaltersSep 13, 2025
    What to do if the Binder Laboratory Equipment controller does not equilibrate to setpoints in Fixed value operation mode?
    • A
      Anthony MorganSep 14, 2025
      If the controller does not equilibrate to setpoints entered in Fixed value operation mode in your Binder Laboratory Equipment, change to Fixed value operation mode.
  • R
    Randall CruzSep 16, 2025
    Why doesn't my Binder Laboratory Equipment controller equilibrate to program set-points?
    • W
      watkinsdiamondSep 16, 2025
      If the controller does not equilibrate to program set-points in your Binder Laboratory Equipment, start the program again. If appropriate, wait for the program delay time.

Summary

General Safety Instructions

Personnel Qualification, Hazards, and Electrical Connection

Details service personnel requirements, potential dangers, and electrical connection specifications.

Maintenance

Troubleshooting

General Electrical Faults

Guides on diagnosing and resolving common electrical issues within the unit.

Heating System Faults

Provides troubleshooting steps for issues related to the unit's heating system.

Cooling System Faults

Offers solutions for identifying and fixing problems within the cooling system.

Humidification Module Errors

Details troubleshooting procedures for various errors in the humidification system.

Repair Work at the Inner and Outer Chamber

Repair Work at the Cooling System

General Information and Tools

Provides safety warnings, required qualifications, and special tools for cooling system repairs.

Calibrating and Adjusting Control Systems

General Calibration and Temperature Control

Covers general calibration steps, setting points, door heating correction, and adjusting the temperature controller.

Humidity Control Calibration and Adjustment

Details calibrating and adjusting the humidity controller, including reset and setting points.

Binder KBF 720 Specifications

General IconGeneral
Temperature fluctuation±0.3 °C
Humidity range10% to 98% RH
Humidity fluctuation±1.5% RH
Voltage230 V
Frequency50/60 Hz
Interior volume700 liters