737 Flight Crew Operations Manual
7.16
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-4Q8-SJA
7.16
PP518, PP519
10 Transponder mode selector . . . . . . . . . . TA ONLY
This step prevents climb commands which can
exceed single engine performance capability.
11 ISOLATION VALVE switch. . . . . . . . . Verify AUTO
This step ensures bleed air is available to both
wings if wing anti-ice is needed.
12 A restart may be attempted if there is N1 rotation
and no abnormal airframe vibration.
13 Choose one:
14 Plan to land at the nearest suitable airport.
►►Go to the One Engine Inoperative Landing
checklist on page 7.30
■ ■ ■ ■
ENGINE FIRE/OVERHEAT DETECTOR FAULT ►►8.18
▼Engine Failure or Shutdown continued▼
Restart is planned:
►►Go to the Engine In-Flight Start
checklist on page 7.22
■ ■ ■ ■
Restart is not planned:
►►Go to step 14
Note: Do not use FMC performance predictions.
December 20, 2018