737 Flight Crew Operations Manual
8.11
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-4Q8-SJA
8.11
12 Choose one:
13 Choose one:
▼
Continued on next page
▼
▼Smoke, Fire or Fumes continued▼
Source of the smoke, fire or fumes is obvious
and can be extinguished quickly:
Isolate and extinguish the source.
If possible, remove power from the affected
equipment by switch or circuit breaker in
the flight deck or cabin.
►►Go to step 13
Source of the smoke, fire or fumes is not obvious
or cannot be extinguished quickly:
►►Go to step 14
Source is visually confirmed to be extinguished
and the smoke or fumes are decreasing:
Continue the flight at the captain’s
discretion.
Restore unpowered items at the captain’s
discretion.
►►Go to the Smoke or Fumes Removal
checklist on page 8.20, if needed
■ ■ ■ ■
Source is not visually confirmed to be
extinguished or smoke or fumes are not
decreasing:
►►Go to step 14