– Zone triggered - alarm / report
– (Zone triggered during exit time no alarm / no report)
– (Zone triggered during entry time alarm / report is delayed for 30 second or entry
time is expired, when system is disarmed before, no report)
3. STAY Arm:
– Zone normal - no alarm / no report
– Zone triggered - alarm / report
– (Zone triggered during exit time no alarm / no report)
– (Zone triggered during entry time alarm / report is delayed for 30 second / entry time
is expired, when system is disarmed before, no report) When zone is triggered, not
bypassed and system is forced to arm, a zone fault report is sent.
– When the system is disarmed and zone is not restored before, a Zone fault restore
report is sent.
02 – Interior Instant
The interior instant zone type performs as described below:
1. Disarm:
– same as the instant zone disarm status
2. AWAY Arm:
– same as the instant zone AWAY arm status
3. STAY Arm:
– This zone will be ignored and performed as disarm. Refer to Keypad Indicators to see
how the zone is displayed during exit time.
– When zone is triggered, not bypassed and system is forced to arm, a zone fault
report is send.
– When system is disarmed and zone is not restored before, a zone fault restore report
is sent.
03 – Delay 1
The delay 1 zone type performs as described below:
1. Disarm: same as instant zone disarm status
2. AWAY Arm:
– Zone normal - no alarm / no report
– Zone triggered - entry time starts - no alarm / no report
– Disarming during entry time - no alarm / no report
– Zone triggered - during exit time - no alarm / no report
– Zone triggered - during entry time - no alarm / no report
– Zone triggered - entry time is expired - alarm / report
– (report is delayed for a specified time (default: 30s; value range: 00-99), when
system is disarmed before, no report)
3. STAY Arm: same as AWAY arm performance.
– First delay zone will start the entry time; all other delay zones will follow.
– When system is disarmed and zone is not restored before, a zone restore report is
sent.
04 – Interior Delay 1
The interior delay 1 zone type performs as described below:
1. Disarm: same as the instant zone disarm status
2. AWAY Arm: same as the delay zone AWAY arm status
AMAX panel
Settings | en 55
Bosch Sicherheitssysteme GmbH Installation Manual 2015.05 | 06 | F.01U.309.277