Control Panels Approved applications | en 107
Bosch Security Systems, Inc. Installation Manual 2018.07 | 10 | F.01U.303.996
– Use a separate D8108A for the two 12 V 7 Ah batteries. When using a D122L Dual Battery
Harness, wire the batteries in parallel and connect the harness to the BAT+ and BAT-
terminals of the control panel.
Rothenbuhler 5110/4001-42 High Security Bell overview
0.64 mm (0.25 in)
minimum distance
+
-
+
-
2
1
1
14
9
7
5
6
8
3
4
10
11
13
12
9
16
15
11
Callout á…³ Description Callout á…³ Description
1 á…³ Self-contained UL listed vibration sensor 9 á…³ D122/D122L
2
2 á…³ Control panel 10 á…³ D126 battery
3 á…³ Accessory modules 11 á…³ D8108A enclosure
4 á…³ High line security module 12 á…³ Proximity/control unit
5 á…³ 4001-42 Balanced Line Module 13 á…³ Normally open (NO)
6 á…³ 5110 Bell 14 á…³ Normally closed (NC)
7 á…³ D133 Relay 15 á…³ End-of-line (EOL) resistor
8 á…³ Alarm input point
1
16 á…³ Safe
1
Use Terminals 1 through 8. (Select only one.)
2
Use a D113 Battery Lead Supervision Module to supervise the battery connections
.