Page #102 background image
11 Restrict/
Protect
Use this function to restrict playback of a recording and/or to protect that
recording from being deleted. The restrict/protect permission can be
individually set for each user account.
Restrict/Protect recording(s) as follows:
Assign a start and end time
Choose channel(s)
Choose checkbox for Restrict and/or Protect
Select <Lock> to lock the segment (the recording appears in a list with
start and end time). Repeat these steps for new recordings as needed.
If required, unlock a recording by selecting its checkbox and select
<Unlock>. Delete a recording permanently with <Delete>
Select <OK> to save the settings (depending on user access, all
restricted/protected recordings will show a blank screen with a lock
logo when playing)
Important: When entering a start and end time for Restrict/Protect
playback, be aware that the selected time may include a portion of a
recorded file. In this case the complete file will be Restricted/Protected. For
example, if you set a start time of 9:30 and an end time of 10:30 then both
the recorded files 9:00 to 10:00 and 10:00 to 11:00 will be selected for
restrict/protect because they both include portions of the selected time
span. The same principle applies if you Delete a time period from 9:30 to
10:30 then both the files 9:00 to 10:00 and 10:00 to 11:00 will be deleted.
12
Record
type
This status line shows the current play mode (or Stop) and a checked box
shows the recording type (Motion, Alarm, Normal, All).
102
en | Operating instructions DIVAR AN 3000 / DIVAR AN 5000
2014.10 | 2.0 | AM18-Q0669 Operations Manual Bosch Security Systems

Table of Contents

Other manuals for Bosch DIVAR AN 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch DIVAR AN 5000 and is the answer not in the manual?

Bosch DIVAR AN 5000 Specifications

General IconGeneral
Motion sensorYes
Total storage capacity2000 GB
Video compression formatsH.264
Analog signal format systemNTSC, PAL
Compatible operating systemsWindows XP, Windows Vista, Windows 7.
Playback resolutions supported960x576, 960x480, 704x576, 704x480, 704x288, 704x240, 352x288, 352x240, 176x144, 176x120
Audio input4
BNC input ports16
USB 2.0 ports quantity1
Ethernet interface typeGigabit Ethernet
HDD interfaceSerial ATA
Maximum HDD capacity3000 GB
Power requirements100-240VAC 50-60Hz
Optical drive includedNo
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 93 %
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)440 x 420 x 70 mm