DS7240-UK Reference Guide Copyright 2003 Bosch Security Systems P/N: 4998122677Cr1 Page 151
PART IV: REFERENCE MATERIALS
60.0 Panel Events and Reporting Formats
The following table includes each panel event, the description for each event as it appears in the panel log, the reports sent for
each event, the zone types linked to the event, and the DSRPS Event Alert Group number. The DSRPS Event Group numbers
also correspond with the Personal Dialing Format Event Group numbers. See Section 55.0 Personal Dialing Format on page
145 for more information.
The last column, Status Reports, indicates System Status events. An “R” indicates that reports for the event follow the System
Status routing. An “S” indicates that the event following the System Status Swinger Count. System reports do not include an
Area number; they use the account number for Area 1.
The event numbers shown in the Panel Events and Reporting Formats table are the same numbers that will show up on a
pager for each corresponding report.
Event #
Event as shown
in Panel Log
SIA Report
SIA Report Data
Contact ID Report Event Description
Zone Types
Linked to Event
DSRPS
Event Group
Status
Reports
01 AC Fail AC Trouble AT 301 AC Loss
AC Power to panel
interrupted.
12 R S
02 AC Restore AC Restoral AR 301 AC Loss AC Power to panel
restored.
12 R S
03 Alarm,Tamper Tamper Alarm ri {area} TA {loop} 137 Tamper Alarm, Tamper Zone
Type.
4-Tamper 3
04 Alarm,Emergency Emergency
Alarm
ri {area} QA {loop} 101 Personal
Emergency
Alarm, Emergency
Zone Type or ABC
key programmed for
emergency response.
5- Emergency
Emergency Key
3
05 Alarm,Panic Panic Alarm ri {area} PA {loop} 120 Panic Alarm, Panic-Visible
Zone Type.
6- Visible Panic
Emergency Key
3
06 Alarm,Invisible Holdup Alarm ri {area} HA {loop} 120 Panic Alarm, Panic- Invisible
Zone Type or ABC
key programmed for
panic response.
7-Invisible Panic
Emergency Key
3
07 Alarm,24-hr Burg Burglary Alarm ri {area} BA {loop} 133 24 Hr Safe Alarm, Burglary Zone
Type.
8- Burglary 3
08 Alarm,Cntrl,Dly Burglary Alarm ri {area} BA {loop} 134 Entry/Exit Alarm, Delay 1 or
Delay 2 Zone Type.
11- Delay 1
12- Delay 2
3
09 Alarm,Cntrl Burglary Alarm ri {area} BA {loop} 130 Burglary
Alarm, Keyswitch or
Follower or Instant
Zone Types.
10- Keyswitch
13- Follower
14- Instant
3
10 Cross,Tamper Burglary Alarm
Cross Zone
ri {area} BM {loop} 137 Tamper Alarm, Tamper Zone
Type with Cross Zone
Option selected.
4-Tamper 3
11 Cross,Emergency
Burglary Alarm
Cross Zone
ri {area} BM {loop}
101 Personal
Emergency
Alarm, Emergency
Zone Type with Cross
Zone Option selected.
5- Emergency 3
12 Cross,Panic Burglary Alarm
Cross Zone
ri {area} BM {loop} 120 Panic Alarm, Panic-Visible
Zone Type with Cross
Zone Option selected.
6- Visible Panic 3
13 Cross,Invisible Burglary Alarm
Cross Zone
ri {area} BM {loop} 120 Panic Alarm, Panic- Invisible
Zone Type with Cross
Zone Option selected.
7-Invisible Panic 3
14 Cross,24hr Burg Burglary Alarm
Cross Zone
ri {area} BM {loop} 133 24 Hr Safe Alarm, Burglary Zone
Type with Cross Zone
Option selected
8- Burglary 3
15 Cross,Cntrl,Dly Burglary Alarm
Cross Zone
ri {area} BM {loop} 134 Entry/Exit Alarm, Delay 1 or
Delay 2 Zone Type
with Cross Zone
Option selected.
11- Delay 1
12- Delay 2
3
16 Cross,Cntrl
Burglary Alarm
Cross Zone
ri {area} BM {loop} 130 Burglary
Alarm, Keyswitch or
Follower or Instant
Zone Types with
Cross Zone Option
selected.
13- Follower
14- Instant
3
Table 42: Panel Events and Reporting Formats