Page 80 P/N: 4998122677Cr1 Copyright 2003 Bosch Security Systems DS7240-UK Reference Guide
PART III: PANEL PROGRAMMING
• Don’t Show Zone Status on Keypads: If not selected (no “••” in option box for this feature), the text keypad displays “OK for
All On” or “OK for Perimeter” across the second line. This indicates that all zones are normal and the system is ready to arm
All On or Perimeter Only.
• If a controlled zone is faulted (either open or shorted), the Area Idle Text for this zone’s assigned area replaces the “OK
for All On” message.
If “Don’t Show Zone Status on Keypads” is selected, the default Area Idle Text (“Not Ready”) should be changed.
See Section 21.8.7 Programming Text Entry Parameters on page 29 for text entry instructions.
• If a zone not configured for Perimeter Only arming is faulted (either open or shorted), “OK for Perimeter” replaces “OK
for All On” on the text keypad’s display. The system may be armed Perimeter Only, but cannot be armed All On until the
faulted zone is restored. See Section 36.4 Options 1, Zone Function ## on page 97 for Zone Function configuration
details.
This option configures the LED keypad to not show zone status when its area is Off (disarmed). Users must press the [*]
key to see zone status.
33.2 Keypad # Area
• Address:
• Keypad 1: 0679
• Keypad 2: 0681
• Keypad 3: 0683
• Keypad 4: 0685
• Keypad 5: 0687
• Keypad 6: 0689
• Keypad 7: 0691
• Keypad 8: 0693
• Default:
• Keypad 1: 1 (Assign Keypad to Area 1)
• Keypads 2-8: 0 (No Area Assigned – Keypad Disabled)
• Selections:
• 0 = No Area Assigned (Keypad Disabled)
• 1 = Assign Keypad to Area 1
• 2 = Assign Keypad to Area 2
• 3 = Assign Keypad to Area 3
• 4 = Assign Keypad to Area 4
33.2.1 Parameter Description
Assign only one area to each keypad. Users (PINs) can be assigned to multiple areas.
The Move to Area function ([#] + [5] + [0]) allows users (PINs) assigned to multiple areas to view those areas from one keypad.