MAP 5000 Initial set-up and programming | en 61
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
Report failure intrusion and
tamper alarm (V1.2x)
Panel has received negative acknowledgment from
communicator as a result of report failure intrusion and
tamper alarm (only for panel firmware 1.2.x)
Report failure summary alarm Panel has received negative acknowledgment from
communicator due to report failure summary alarm
Report failure summary trouble Panel has received negative acknowledgment from
communicator due to report failure trouble
Report failure duress alarm Panel has received negative acknowledgment from
communicator due to report failure duress alarm
Report failure hold-up alarm Panel has received negative acknowledgment from
communicator due to report failure hold-up alarm
Report failure amok alarm Panel has received negative acknowledgment from
communicator due to report failure amok alarm
Report failure intrusion and
tamper alarm
Panel has received negative acknowledgment from
communicator due to report failure intrusion and tamper
alarm
Report failure panel alarm Panel has received negative acknowledgment from
communicator due to report failure panel alarm
Internal tamper alarm Tamper alarm from disarmed area
External tamper alarm Tamper alarm from armed area
Bypass At least one device is bypassed
Disable At least one device is disabled
Management system interface
trouble
Trouble in connection to management system
Present mode ON The area programmed as present/absent is disarmed
Blocking time active Blocking time is active for one or more areas
Wrong login The maximum number of permitted passcode input
attempts on a control center was exceeded
User active A defined user is logged in at a defined control center
External fire alarm Fire alarm from armed area
Internal fire alarm Fire alarm from disarmed area
External fire trouble Fire device trouble from armed area
Internal fire trouble Fire device trouble from disarmed area
Walk test Walk test is active
Motion detector test Motion detector test is active in one or more areas
Exit delay active From start of exit delay until
end of exit delay
arming of the area