Entry delay active From start of entry delay until
end of entry delay
disarming of the area
Reportable duress alarm Reporting of duress alarm event
Reportable hold-up alarm Reporting of hold-up alarm event
Reportable amok alarm Reporting of amok alarm event
Reportable external intrusion
alarm
Reporting of external intrusion alarm event, possibly also
delayed if present/absent option is used
Reportable external tamper
alarm
Reporting of external tamper alarm event, possibly also
delayed if present/absent option is used
Reportable panel summary
trouble
Reporting of panel summary trouble event, possibly also
delayed if present/absent option is used
Reportable panel summary
armed
Reporting of panel summary armed
Reportable external fire alarm Reporting of duress alarm event, possibly also delayed if
present/absent option is used
Anti-mask intrusion trouble Covering of a motion detector
External tamper alarm disarmed Tamper alarm from disarmed area with simultaneous
reporting via the communicator
Transmission path fault In the event of communication failure between
communicator and receiver
Ethernet path layer1 fault In the event of failure of connection to network connector
Wireless path layer1 fault In the event of failure of connection to network
field strength insufficient
registration not possible
GPRS service not available
no connection to the DE module
IPC reporting failure No acknowledgment received from the receiver within 240
sec.
S1S Transmission Path Fault Communication failure between panel and communicator
S1S Reporting Failure Panel has received negative acknowledgment from
communicator
Open Intrusion Interface
Trouble
Trouble in connection via Open Intrusion Interface
Silence Area x Silence sirens and buzzer of area x
Reset Area x Clear events of area x