34/68 Installation
Bosch Rexroth AG, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
13
R(L)
1
R(L)
2
T
1
T
2
h
min
h
t min
S SB
Fig. 14: Inside-reservoir installation A20VO size 520 with installation position 13
R(L)
1
,
R(L)
2
Air bleed port h
t min
Minimum required immersion depth
(200 mm)
T
1
, T
2
Drain port h
min
Minimum required distance
toreservoir bottom (100 mm)
S Suction port SB Baffle (baffle plate)
Table 13: Inside-reservoir installation
Installation position Air bleed Filling
13 (drive shaft horizontal) via the highest open port R(L)
1
automatically via the open
portR(L)
1
and S, by position
below the hydraulic fluid level
7.3.3 Above-reservoir installation
Above-reservoir installation means that theaxial piston unit isinstalled above
theminimum fluid level ofthereservoir.
Observe themaximum permissible suction heighth
Smax
= 800mm. The
permissible suction heighth
S
is derived from the total pressure loss.
Because complete air bleeding and filling are not possible in installation
positions16 and 17, the axial piston unit should be air bled and filled in a
horizontal position before installation.
To prevent the axial piston unit from draining, a height difference h
ESmin
of at least
25 mm at portF is required in installation position14 and 15.