Troubleshooting 61/68
RE 93100-01-B/2019-09-10, A20V(L)O Series 1, Bosch Rexroth AG
14.2 Malfunction table
Table 21: Axial piston unit malfunction table
Malfunction Possible cause Remedy
Unusual noises Insufficient air bleeding ofthehydraulic system Fill theaxial piston unit, suction line for
thehydraulic pump and thereservoir
Completely air bleed theaxial piston unit and
hydraulic system
Check correct installation position
Insufficient suction conditions, e.g. insufficient
dimensioning ofthesuction line, viscosity
ofthehydraulic fluid too high, suction height
too high, suction pressure too low, foreign
particles inthe suction line, impermissible filter
inthe suction line
Machine/system manufacturer: Check
thesystem, e.g. optimize inlet conditions,
usesuitable hydraulic fluid
Fill thesuction line with hydraulic fluid
Remove foreign particles from thesuction line
Drive speed too high Machine/system manufacturer:
Reducedrivespeed
Wrong direction ofrotation Machine/system manufacturer: Check correct
direction ofrotation, see chapter 7.4.1
"Preparation" onpage36
Improper mounting oftheaxial piston unit Check themounting oftheaxial piston unit
according tothe specifications ofthemachine/
system manufacturer – observe tightening
torques
Improper mounting ofassembled parts,
hydraulic lines orimproper installation
ofthecoupling
Fasten assembled parts according tothe
information provided bythecoupling fitting
manufacturer
Valve and controller vibrate Optimize theadjustment ofthecontroller
oftheaxial piston unit and thepressure
limitation inthe hydraulic system
Mechanical damage tothe axial piston unit
(e.g.bearing damage)
Replace axial piston unit
Contact BoschRexroth Service
Increased, unusual vibration Bearings worn Contact BoschRexroth Service