28/68 Installation
Bosch Rexroth AG, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
7 Installation
Prior toinstallation, thefollowing documents should betohand:
Installation drawing for theaxial piston unit (can beobtained from your contact
person atBoschRexroth)
Hydraulic circuit diagram for theaxial piston unit (in theinstallation drawing)
Hydraulic circuit diagram for themachine/system (available from themachine/
system manufacturer upon request)
Order confirmation (contains theorder-related technical data for your
axialpistonunit)
of the axial piston unit (contains the permissible technical data)
7.1 Unpacking
The axial piston unit comes inapolyethylene material (PE) corrosion protection film.
CAUTION! Danger due tofalling parts!
Ifthepackaging isnot opened correctly, parts may fall out and damage theparts
oreven result ininjury.
Place thepackaging ona level surface with sufficient load-bearing capacity.
Only open thepackaging from thetop.
Remove thepackaging from theaxial piston unit.
Check theaxial piston unit for transport damage and completeness; see chapter4
"Scope ofdelivery" onpage19.
Dispose ofthepackaging inaccordance with theregulations inyour country.
7.2 Installation conditions
The installation position and location oftheaxial piston unit essentially determine
how itisinstalled and commissioned (such aswhen filling and air bleeding
theaxialpiston unit).
Fasten theaxial piston unit sothat theexpected forces and torque can
betransferred without any danger. The machine/system manufacturer
isresponsible for sizing thefasteners.
Observe thepermissible radial forces onthe drive shaft when driving with radial
loading (belt drives). If necessary, store thebelt pulley separately.
Make sure theaxial piston unit isalways filled with hydraulic fluid during
commissioning and operation. Also do this also after relatively long standstill
periods, since theaxial piston unit may drain out through thehydraulic lines.
Direct theleakage inthe housing area tothe reservoir through thehighest
drainport. Use aline size that matches theport.
A check valve inthe drain line isonly permissible ona case-by-case
basis following consultation. Please consult your proper contact person
atBoschRexroth.
To keep noise values low, use elastic elements toisolate all connecting lines from
all vibration-capable components (e.g. reservoir).
Make sure thesuction, drain, and return lines flow into thereservoir below
theminimum fluid level under all operating conditions. This will prevent air from
being drawn inand foam from forming.