7.4.7 Completion of assembly
1. Remove any installed transport screws.
CAUTION! Operation with protective plugs!
Operating theaxial piston unit with protective plugs may result ininjury ordamage
tothe axial piston unit.
▶ Before commissioning, remove all protective plugs and replace them with
suitable, pressure-resistant, metal threaded plugs orconnect theappropriate
lines.
2. Remove thetransport protection.
The axial piston unit isdelivered with protective covers(1) and protective
plugs(2). They are not pressure-resistant and have tobe removed prior
toconnection. Use asuitable tool for this toprevent damage tothe sealing
and functional surfaces. If sealing orfunctional surfaces are damaged, contact
your BoschRexroth service partner ortheservice department oftheplant that
manufactured theaxial piston unit.
1 12
3
Fig. 18: Removing transport protection (e.g. A20VLO, size 260)
1 Protective covers
2 Protective plugs/threaded plugs
3 For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/orthreaded
plugs, which serve astransport protection. All ports required for functional
operation must be connected (see Table 16, Table 17 and Table 18 on
page44). Failure todo socould lead tomalfunctions ordamage. If aport isnot
being used, plug itwith athreaded plug since theprotective plugs are not
pressure-resistant.
Adjusting the setting screws will render the warranty void. If you need tochange
thesettings, please contact your local contact person; you can find their contact
information at
www.boschrexroth.com/addresses
3. For versions with through drive, install theauxiliary pump according tothe
pump manufacturer's instruction manual. The protective cover(3) isnot