40/68 Installation
Bosch Rexroth AG, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
7.4.7 Completion of assembly
1. Remove any installed transport screws.
CAUTION! Operation with protective plugs!
Operating theaxial piston unit with protective plugs may result ininjury ordamage
tothe axial piston unit.
Before commissioning, remove all protective plugs and replace them with
suitable, pressure-resistant, metal threaded plugs orconnect theappropriate
lines.
2. Remove thetransport protection.
The axial piston unit isdelivered with protective covers(1) and protective
plugs(2). They are not pressure-resistant and have tobe removed prior
toconnection. Use asuitable tool for this toprevent damage tothe sealing
and functional surfaces. If sealing orfunctional surfaces are damaged, contact
your BoschRexroth service partner ortheservice department oftheplant that
manufactured theaxial piston unit.
1 12
3
Fig. 18: Removing transport protection (e.g. A20VLO, size 260)
1 Protective covers
2 Protective plugs/threaded plugs
3 For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/orthreaded
plugs, which serve astransport protection. All ports required for functional
operation must be connected (see Table 16, Table 17 and Table 18 on
page44). Failure todo socould lead tomalfunctions ordamage. If aport isnot
being used, plug itwith athreaded plug since theprotective plugs are not
pressure-resistant.
Adjusting the setting screws will render the warranty void. If you need tochange
thesettings, please contact your local contact person; you can find their contact
information at
www.boschrexroth.com/addresses
3. For versions with through drive, install theauxiliary pump according tothe
pump manufacturer's instruction manual. The protective cover(3) isnot
pressure-resistant and should not beused during operation.